{"id":3917,"date":"2026-11-25T16:25:41","date_gmt":"2026-11-25T08:25:41","guid":{"rendered":"http:\/\/www.jhyouthcenter.com\/blog\/?p=3917"},"modified":"2026-11-25T16:25:41","modified_gmt":"2026-11-25T08:25:41","slug":"how-to-minimize-cogging-torque-in-pmsm-4804-50bd44","status":"publish","type":"post","link":"http:\/\/www.jhyouthcenter.com\/blog\/2026\/11\/25\/how-to-minimize-cogging-torque-in-pmsm-4804-50bd44\/","title":{"rendered":"How to minimize cogging torque in PMSM?"},"content":{"rendered":"<p>Hey there, if you\u2019ve ever messed around with permanent magnet synchronous motors (PMSMs), you know that cogging torque can be such a headache. It\u2019s that weird, jerky feeling when the motor starts spinning, right? Like it\u2019s fighting to turn instead of gliding smoothly. As someone who\u2019s been in the PMSM supplier game for years\u2014speaking from actual experience, not just textbook stuff\u2014I\u2019ve spent way too many late nights troubleshooting this, and today I\u2019m breaking down how to minimize it. No fancy jargon overload, just real, actionable tips that actually work for real motors. <a href=\"https:\/\/www.simomotor.com.cn\/permanent-magnet-synchronous-motor\/\">Permanent Magnet Synchronous Motor<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.simomotor.com.cn\/uploads\/37189\/small\/3-phase-induction-motor-slip-ring5f5cd.jpg\"><\/p>\n<p>First, let\u2019s cut through the confusion: what even is cogging torque? You\u2019ve got a stator (the stationary part with coils) and a rotor (the spinning part with permanent magnets, duh). Cogging torque happens because of the magnetic attraction between the stator teeth and the rotor magnets. It\u2019s not from the current flowing through the coils\u2014that\u2019s torque for doing work. Cogging is purely from the magnetic pull when the motor\u2019s not energized, and it causes that stutter at low speeds, noise, even vibration over time. For applications like robotics, electric power steering, or any precision machinery, that\u2019s a non-starter. So how do we fix it? Let\u2019s dive into the practical stuff, not just theory.<\/p>\n<p>First up: skew the stator or rotor. This is the oldest trick in the book, but it still works like a charm if done right. Skewing means twisting the stator teeth or the rotor magnets slightly along the axis of the motor. Wait, why does that help? Each magnet interacts with a set of teeth at a slightly different angle, so their individual magnetic pulls cancel each other out instead of adding up to that big cogging spike. Now, I\u2019ve seen suppliers botch this before\u2014they just skew by one stator slot pitch, but if you do that, you might reduce cogging, but you can mess up the back-EMF (that\u2019s the voltage the motor makes when spinning, important for efficiency) too. The sweet spot? Usually skewing by one slot per pole pair, but sometimes you\u2019ve got to adjust it based on the number of slots and poles. For example, a motor with 12 stator slots and 8 rotor poles\u2014common setup\u2014skewing either the stator or rotor by half a slot pitch will knock cogging down by like 70-80% without killing performance. Pro tip from the shop floor: don\u2019t over-skew. I once had a client who wanted extra smooth motion, so we skewed too much, and their motor\u2019s efficiency dropped 3%\u2014that\u2019s a big hit for a battery-powered device. So balance is key here.<\/p>\n<p>Next, optimize the slot and pole combination. This is more about design upfront, right? If you\u2019re already building a motor, you can\u2019t change the number of slots and poles easily, but if you\u2019re working with a supplier (wink wink, nudge nudge), this is the first thing we check. Cogging torque\u2019s magnitude depends on the least common multiple (LCM) of the number of stator slots (Ns) and rotor poles (Nr). Let\u2019s do a quick math check: if Ns=12 and Nr=8, LCM is 24. If Ns=12 and Nr=10, LCM is 60. Wait, higher LCM = lower cogging torque, right? Because the magnetic interactions repeat less often, so they cancel out more. But it\u2019s not just LCM\u2014there\u2019s something called the \u201cgreatest common divisor (GCD)\u201d too. If GCD of Ns and Nr is big, that means the slots and poles align more frequently, which makes cogging worse. So for example, Ns=12, Nr=8: GCD is 4. If Ns=12, Nr=11, GCD is 1. That tiny change? Huge difference in cogging. Now, I\u2019m not saying you have to throw out your entire motor design to swap pole counts\u2014especially if it\u2019s already optimized for speed or torque output\u2014but when you\u2019re customizing a motor for a new client, this is the first design tweak we test. I had a customer last year making a small drone motor, originally with 10 slots and 12 poles (GCD 2, LCM 60). We swapped to 12 slots and 14 poles (GCD 2, LCM 84), and their cogging dropped almost 50% without any other changes. Game changer for their smooth flight performance.<\/p>\n<p>Then there\u2019s shaping the stator teeth and rotor magnets. This is where we get into actual physical design tweaks that make a big difference. Stator teeth that are perfectly rectangular? Bad for cogging. If you shape the teeth so their width tapers a bit, or you chamfer the edges, you can make the magnetic gap between the stator and rotor more uniform, which reduces that uneven attraction. For the rotor magnets, instead of using perfectly straight, rectangular magnets, we can arc them to match the rotor\u2019s outer surface, or even use \u201cskewed magnets\u201d which ties back to the first tip. Wait, another trick with magnets: not making them exactly the same size or shape. Call it \u201cmagnet pairing\u201d or \u201cmagnet grading,\u201d but if you use slightly different magnet strengths in adjacent poles, or vary their arc length a tiny bit, you can break up the consistent magnetic pattern that causes cogging. I\u2019ve found that varying each magnet by just 2-3% in arc length is enough to knock cogging down another 10-15% without affecting the motor\u2019s overall power. Just last month, we did this for a client making medical pump motors\u2014they needed zero cogging for precise flow, and this tweak pushed their cogging to almost unmeasurable levels, way better than their previous supplier\u2019s motor. Oh, and don\u2019t forget the air gap! Making the air gap (the space between stator and rotor) as consistent as possible is big. If the gap varies by even 0.1mm, that creates uneven magnetic pull, so precision machining here pays off. No one thinks about that, but it\u2019s one of the cheapest fixes if you\u2019re already machining the stator and rotor.<\/p>\n<p>Wait, what if you\u2019re working with an existing motor that\u2019s already built, and you can\u2019t change the design? Is there a way to minimize cogging then? Yeah, there are some operational tweaks and add-ons. First, you can adjust the drive control parameters. Cogging torque is most noticeable at low speeds, so if you tune the motor\u2019s controller to add a tiny bit of current ripple in sync with the cogging frequency, it can cancel out that stutter. A lot of cheap controllers don\u2019t have this feature, but if you\u2019re using a quality drive (which we supply, by the way), you can tweak the \u201clow-speed torque compensation\u201d setting. Another trick for existing motors: adding a \u201cdummy slot\u201d or modifying the stator slots slightly. That\u2019s not for mass production, but if you have a prototype or a small batch, you can mill a small notch in the stator teeth to break up the magnetic alignment. I\u2019ve done this for a client who had a few old motors that were causing vibration in their conveyor system\u2014mill a tiny notch in every other stator tooth, and the vibration dropped by 60% instantly. It\u2019s not a permanent fix for mass production, but it works for short-term or custom projects.<\/p>\n<p>Now, let\u2019s talk about common mistakes suppliers (and even engineers) make when trying to fix cogging. First, over-skewing like I mentioned earlier. I\u2019ve seen a supplier skew a motor so much that the back-EMF went down, so they had to add more current to get the same torque, which wasted energy and made the motor hotter. Second, ignoring magnet quality. If you\u2019re using cheap, low-grade magnets that have inconsistent magnetic strength, even the best design tweaks won\u2019t fix cogging. We use sintered neodymium magnets with strict quality control\u2014each magnet\u2019s flux is tested before it goes into the rotor, so we don\u2019t have that variation messing things up. Third, not testing at actual operating conditions. A lot of engineers test cogging with the motor unloaded, but when you put a load on it, the cogging changes. You need to test with the actual load the motor will see, because the mechanical load can alter the magnetic alignment. I once had a client say their motor had terrible cogging at no load, but when we tested it under their actual pump load, it was smooth\u2014turns out their load was counteracting the small amount of residual cogging.<\/p>\n<p>Wait, let\u2019s get back to why this matters for you, not just theory. If you\u2019re a design engineer working on a robot arm, that tiny cog can make the arm move too far and damage a part. If you\u2019re making an electric scooter, cogging makes the start-up jerky, which is unsafe and annoying. If you\u2019re a medical device maker, cogging can ruin precise dosage delivery. For us as a PMSM supplier, our whole job is to make sure our motors work for your application, so we don\u2019t just send you a motor and say \u201cgood luck.\u201d We work with you to tailor the design\u2014whether it\u2019s slot\/pole count, magnet shaping, skew\u2014so that the cogging is as low as you need it to be. We\u2019ve got a range of standard motors, but we customize the tweaks I mentioned to fit your needs, not just a one-size-fits-all design.<\/p>\n<p>Let me throw in a real example from our shop. Last quarter, we had a client making collaborative robots (cobots) that needed super smooth joint movement. Their previous motor supplier gave them 12-slot, 10-pole PMSMs with cogging torque of ~0.8 Nm\u2014way too much for cobots, which have to handle delicate interactions with humans. We redesigned the stator to 12 slots, 14 poles, skewed the rotor by half a slot pitch, and used slightly tapered stator teeth. The result? Cogging dropped to 0.12 Nm\u2014way below their requirement, and they were able to use our motors for all 6 of their cobot joints. They told us it cut their vibration by 80% and made their cobots way easier to program for delicate tasks. That\u2019s the stuff that matters, right? Not just numbers, but real results for your product.<\/p>\n<p>Another thing: when you\u2019re choosing a PMSM supplier, don\u2019t just look at price. Ask them about their cogging mitigation process. Do they test for cogging at different load levels? Do they offer custom design tweaks? A lot of cheap suppliers cut corners on design testing, so their motors have hidden cogging that shows up once you put them in your product. We run every motor we build through a cogging torque test rig\u2014we spin the rotor at low speed (where cogging is worst) and measure the torque variation, so we can guarantee that it meets your requirements. No surprises, no reworks down the line.<\/p>\n<p>Wait, let\u2019s wrap this up with a quick recap, because I know this is a lot. Minimizing cogging torque in PMSMs boils down to four main areas: first, skew the stator or rotor at the right amount (not too much, not too little). Second, optimize the slot and pole combination for high LCM and low GCD. Third, shape stator teeth and rotor magnets (tapering teeth, arcing magnets, varying magnet size\/strength) to reduce magnetic alignment. Fourth, tune your control system if you\u2019re using an existing motor. And if you\u2019re working with a supplier like us, we can handle all that design and testing so you don\u2019t have to.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.simomotor.com.cn\/uploads\/37189\/small\/cooling-ic-41190578.jpg\"><\/p>\n<p>Now, if you\u2019re working on a project where smooth motor performance is non-negotiable\u2014whether it\u2019s robotics, medical devices, e-mobility, or anything else\u2014we can help you fine-tune a PMSM that has minimal to zero cogging. We don\u2019t do generic motors here; every motor we build is tailored to your specific application, with the right tweaks to eliminate that annoying jerky motion. Reach out to our team to talk through your project needs, and we\u2019ll walk you through the best solutions to get the smooth, reliable motor performance you need. Don\u2019t let cogging torque hold your project back\u2014let\u2019s work together to solve it.<\/p>\n<p><a href=\"https:\/\/www.simomotor.com.cn\/low-voltage-ac-motor\/\">Low Voltage AC Motor<\/a> References:<\/p>\n<ol>\n<li>Zhu, Z. Q., &amp; Howey, D. A. (2018). Permanent Magnet Synchronous Motors: Design, Control, and Applications. IEEE Press.<\/li>\n<li>El-Refaie, A. M. (2015). Torque Ripple in Permanent Magnet Synchronous Machines: A Review. IEEE Transactions on Industry Applications, 51(3), 2288-2300.<\/li>\n<li>Bianchi, N., &amp; Bolognani, S. (2002). Design Techniques to Reduce the Cogging Torque of Permanent Magnet Brushless Motors. IEEE Transactions on Energy Conversion, 17(1), 34-40.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.simomotor.com.cn\/\">Xi\u2019an Simo Motor Co., Ltd.<\/a><br \/>Xi\u2019an Simo Motor Co., Ltd. is well-known as one of the leading permanent magnet synchronous motor manufacturers and suppliers in China. Please feel free to buy high-grade permanent magnet synchronous motor in stock here and get quotation from our factory. All customized products are with high quality and low price.<br \/>Address: No. 159 Mingguang Road Economic and Technological Development Zone, Xi&#8217;an, Shaanxi Province, China<br \/>E-mail: mkt-sales@simo.com.cn<br \/>WebSite: <a href=\"https:\/\/www.simomotor.com.cn\/\">https:\/\/www.simomotor.com.cn\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey there, if you\u2019ve ever messed around with permanent magnet synchronous motors (PMSMs), you know that &hellip; <a title=\"How to minimize cogging torque in PMSM?\" class=\"hm-read-more\" href=\"http:\/\/www.jhyouthcenter.com\/blog\/2026\/11\/25\/how-to-minimize-cogging-torque-in-pmsm-4804-50bd44\/\"><span class=\"screen-reader-text\">How to minimize cogging torque in PMSM?<\/span>Read more<\/a><\/p>\n","protected":false},"author":569,"featured_media":3917,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3880],"class_list":["post-3917","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-permanent-magnet-synchronous-motor-4448-52312e"],"_links":{"self":[{"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/posts\/3917","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/users\/569"}],"replies":[{"embeddable":true,"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/comments?post=3917"}],"version-history":[{"count":0,"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/posts\/3917\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/posts\/3917"}],"wp:attachment":[{"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/media?parent=3917"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/categories?post=3917"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.jhyouthcenter.com\/blog\/wp-json\/wp\/v2\/tags?post=3917"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}